Cracking Resistance Control
  1. Seat
  2. Rubber seating
  3. Poppet valve
  4. Counter balance cylinder
  5. Lever
  6. Cracking resistance control
Picture of Cracking Resistance Control (CRC)
The ATX200, ATX100 and ATX50 second stages feature Cracking Resistance Control (CRC). This feature adjusts the spring load on the poppet vavle assembly and varies the cracking resistance. This can be adjusted during the dive to suit individual diver preference.